QL355英國tti直流穩(wěn)壓電源,英國tti QL355
如果你感興趣的話,可以電話:0755-33217630 33217631
產品名稱:QL355英國tti直流穩(wěn)壓電源,英國tti QL355
產品型號:QL355
產品廠商:深圳市深東金儀器有限公司
簡單介紹
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:Bench/System High Precision DC Power Supply, Linear Regulation, Digital Control 35V/3A or 15V/, No Interfaces
QL355英國tti直流穩(wěn)壓電源,英國tti QL355的詳細介紹
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
Bench/System High Precision DC Power Supply, Linear Regulation, Digital Co ntrol 35V/3A or 15V/, No Interfaces
ntrol
The QL Series II is the latest and highest performance linear regulated power supply series from TTi.
Single and triple output models are available. Each model can be specified with or without digital remote co ntrol interfaces.
Each main output provides more than 100 watts of power, and dual range capability offers higher currents at lower voltages.
New features include an enhanced auxiliary output with fully variable voltage and higher current capability on T models, and an LXI compliant LAN interface on all P models.
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
TECHNICAL SPECIFICATIONS
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
Accuracy specifications apply for the temperature range 18°C to 28°C after one hour warm-up.
Thurlby Thandar Instruments Ltd. operates a policy of co ntinuous development and reserves the right to alter specifications without prior notice.
Bench/System High Precision DC Power Supply, Linear Regulation, Digital Co
- Advanced dc power supplies, single or triple output
- Up to 112 watts per output
- Very high precision, very low noise, excellent dynamics
-
Advanced user interface with numeric and rotary co
ntrol - Multiple voltage/current ranges for increased flexibility
- Multiple non-volatile memories for power supply set-ups
- Switchable remote sense provides perfect load regulation
- Comprehensive protection including OVP and OCP trips
- Compact bench footprint; modular width for rack mounting
-
Auxiliary output fully variable 1.00V to 6.00V at 3A with selec
table voltage and current metering (T models) - Bus programmable via USB, RS232, GPIB or LAN (P models)
- LAN interface is LXI compliant
- Duplicate power and sense terminals at rear (P models)
Single and triple output models are available. Each model can be specified with or without digital remote co
Each main output provides more than 100 watts of power, and dual range capability offers higher currents at lower voltages.
New features include an enhanced auxiliary output with fully variable voltage and higher current capability on T models, and an LXI compliant LAN interface on all P models.
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
MODEL TABLE | ||||||
---|---|---|---|---|---|---|
MODEL | OUTPUTS | MAIN OUTPUTS | AUX OUT | MAX POWER | INTERFACES | TERMINALS |
QL355 | 1 | 0-35V/0-3A or 0-15V/0- | - | 105W | - |
Front o |
QL564 | 1 | 0-56V/0-2A or 0-25V/0-4A | - | 112W | - |
Front o |
QL355T | 3 | 2 x 0-35V/0-3A or 0-15V/0- | 1-6V/3A | 228W | - |
Front o |
QL564T | 3 | 2 x 0-56V/0-2A or 0-25V/0-4A | 1-6V/3A | 242A | - |
Front o |
QL355P | 1 | 0-35V/0-3A or 0-15V/0- | - | 105W | RS232/USB/GPIB/LAN | Front/Rear |
QL564P | 1 | 0-56V/0-2A or 0-25V/0-4A | - | 112W | RS232/USB/GPIB/LAN | Front/Rear |
QL355TP | 3 | 2 x 0-35V/0-3A or 0-15V/0- | 1-6V/3A | 228W | RS232/USB/GPIB/LAN | Front/Rear |
QL564TP | 3 | 2 x 0-56V/0-2A or 0-25V/0-4A | 1-6V/3A | 242A | RS232/USB/GPIB/LAN | Front/Rear |
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
TECHNICAL SPECIFICATIONS
MAIN OUTPUT(S) | |
---|---|
QL355, QL355P, QL355T, QL355TP | |
Max. Output Power | 105 watts |
Output Ranges |
Range 1 - 0 to 35V, 0 to 3A Range 2 - 0 to 15V, 0 to Range 3 - 0 to 35V, 0 to 500.0mA |
QL564, QL564P, QL564T, QL564TP | |
Max. Output Power | 112 watts |
Output Ranges |
Range 1 - 0 to 56V, 0 to 2A Range 2 - 0 to 25V, 0 to 4A Range 3 - 0 to 56V, 0 to 500.0mA |
All Models | |
Voltage Setting | By floating point numeric entry or rotary jog wheel; resolution 1mV |
Current Setting | By floating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range |
Setting Accuracy |
Voltage - 0.03% ±5mV Current 0.2% ±5mA/0.5mA |
Output Mode |
Operation in co |
DC Output Switch | Sets output voltage and current levels to zero when Off |
Output Terminals | 4mm safety binding post terminals on 19mm (0.75") spacing. Duplicated on rear terminal block (P versions only) |
Load Regulation |
For any load change, at the output terminals, using remote sense, Voltage <0.01% + 2mV. Current <0.01% + 250μA; <0.01% +50μA on 500mA range. (Add typically 2.5mV for a 0.5V dro |
Line Regulation | Voltage <0.01% + 2mV for 10% change.Current <0.01% +250μA; <0.01%+ 50μA on 500mA range |
Ripple and Noise | Typically <0.35mV rms CV mode, and <0.2mA rms CI mode (<20μA rms on 500mA range) |
Common Mode Noise Current | <4μA rms at 20MHz bandwidth |
Transient Respo |
<20usec to within 15mV of setting for 90% load change |
Temperature Coefficient | <(50ppm+0.5mV)/ °C (voltage), <(100ppm+1mA/0.1mA)/°C (current) |
Remote Sense | Eliminates up to 0.5V drop per lead. Remote sense operation selected from front panel and indicated by LED |
Sense Terminals | Recessed sprung sockets for direct insertion of wires. Duplicated on rear terminal block (P versions only) |
OUTPUT PROTECTION | |
---|---|
Output Protection | Output will withstand forward voltages of up to 20V above rated output voltage. Reverse protection by diode clamp for currents up to 3A |
Fault Co |
The output will be shut down if any of the four trip co |
Over Voltage (OVP) | Settable 1V to 40V (QL355) or 60V (QL564) in 0.1V steps |
Over Current (OCP) | Settable 0.1A to 5. (QL355) or 4. (QL564) in 0.01A steps |
Over Temperature |
Mo |
Sense Error |
Mo |
Trip Output Signal | Isolated open-collector output signal on rear panel |
METERING | |
---|---|
Display Type |
Dual digital displays per output using 14mm (0.56") high brightness LEDs. 5 digits for voltage, 4 digits for current. Updat |
Meter Function |
Voltage meter shows set voltage when in CV mode and measured voltage when in CI mode. Current meter shows measured current when in CV mode and set current when in CI mode. |
Limits Display |
With the dc output switch set to Off, both meters show the set values (i.e. the limits). With the output On, either the voltage meter or current meter will show a measured value (depending on the CV/CI mode). Pressing the Limits button will provide a temporary display of the set values. |
Watts (VxA) Display | The voltage meter can be made to show the calculated product of voltage and current |
Meter Resolution | |
Voltage | 1mV (CV mode) or 10mV (CI mode) |
Current | 1mA or 0.1mA depending on range |
Power | 0.01W or 0.001W depending on range |
Meter Accuracy | |
Voltage | 0.1% of reading ±10 mV (CI mode) |
Current | 0.2% of reading ± 0.00 or 0.5mA (CV mode) |
Power | 0.3% of reading ± 0.05W or 0.005W |
SETTINGS MEMORIES | |
---|---|
Main Output(s) | Up to 50 set-ups per output can be saved and recalled via the keyboard or remote interfaces. |
Parameters Stored | Range, Set volts, Set current, OVP, OCP |
Recall system |
Settings are previewed o |
l |
On triple output models when in l |
Auxiliary Output | Up to 10 voltage settings can be saved and recalled via the keyboard or remote interfaces |
ALARM OUTPUT |
---|
Isolated rear-panel open-collector output signal. User can select output to be activated for either OVP, OCP, Overtemperature or Sense miswiring, or for any of those four faults. |
l |
---|
(Triple Output Models) Each output can be co l A Copy function is available which copies all of the settings for output 1 to output 2 (Range, Set volts, Set current, OVP, OCP). l (Note: l |
AUXILIARY OUTPUT | |
---|---|
(Triple Output Models) | |
Output Voltage | 1.00 to 6.00V |
Output Current | >3.0 A maximum. LED indication of over-current |
DC Output Switch | Sets output voltage level to zero when Off |
Setting Accuracy | 0.5% ±10mV |
Ripple and Noise | <2mV rms, 10mVp-p |
Load Regulation | < 1% for 90% load change |
Line Regulation | < 0.1% for 10% line change |
Meter Accuracy |
Voltage 0.5% ±10mV, Resolution 10mV Current 0.5% ±10mA, Resolution 10mA |
Output Regulation |
Switch-mode down co |
Output Protection | Output will withstand up to 16 V forward voltage. Diode clamped for reverse voltages and 1 Amps reverse current |
Output Terminals | 4mm safety binding post terminals on 19mm (0.75") spacing. Duplicate screwless terminals at rear (P versions only) |
DIGITAL BUS INTERFACES | |
---|---|
(P suffix versions only) Full remote co |
|
RS-232 | Standard 9-pin D connector. Baud rate variable 600 to 19,200 |
USB |
USB 2.0 co |
GPIB (IEEE-488) |
The interface co |
Ethernet (LAN) |
Standard 10/100 ba |
LXI Compliance | LAN interface is compliant with LXI class C. (LXI is the abbreviation for Lan eXtensions for Instrumentation). For more information visit: www.tti-test.com/go/lxi |
DIGITAL PROGRAMMING PERFORMANCE | |
---|---|
(P versions only) | |
Voltage Setting - Main Output(s) | |
Resolution/Accuracy | 1mV / ± (0.03% +5mV) |
Current Setting - Main Output(s) | |
Resolution/Accuracy | 0.1mA / ± (0.2% +5mA) or 0.01mA / ± (0.2% +0.5mA) on 500mA range |
Voltage Setting - Auxiliary Output (Triple Output Models) | |
Resolution/Accuracy | 10mV / ± (0.5% +10mV) |
Programming Speed | |
Command Delay | Typically <25ms (this must be added to any of the figures below) |
Voltage Up Time | <10ms* to 1% |
Voltage Down Time | <40ms* to 1% (full load); <0.6s* to 1% (no load) |
* The up and down times vary with range and voltage step size. More information is co |
QL355英國tti直流穩(wěn)壓電源,英國tti QL355:
DRIVER SOFTWARE SUPPLIED (P versions only) | |
---|---|
IVI Driver |
An IVI driver for Windows is supplied. This provides support for common applications such as LabView*, LabWindows*, HPVEE* etc. |
USB Driver | An installation file is supplied which calls a standard Windows* USB driver. |
* LabView and LabWindows are trademarks of Natio HPVEE (now Agilent VEE) is a trademark of Agilent Technologies. * USB interface is supported for Windows 2000, XP, Vista and Windows 7. Further versions will be supported as they are released. Windows is a trademark of Microsoft. |
KEYBOARD & ROTARY Co |
---|
All functions, including the selec |
GENERAL SPECIFICATIONS | |
---|---|
AC Input | 230V AC or 115V AC ± 10%, 50/60HzInstallation Category II |
Input Power |
Single - 250VA max. Triple - 500VA max |
Temperature & Enviro |
|
Operating Range | +5°C to +40°C, 20% to 80% RH |
Storage Range | -40°C to + 70°C |
Enviro |
Indoor use at altitudes up to 2000m, Pollution Degree 2 |
Cooling | Intelligent variable-speed fan. Over-temperature trip shuts down output if internal temperatures exceed predetermined thresholds. |
Safety & EMC | |
Safety | Complies with EN61010-1 |
EMC | Complies with EN61326 |
PHYSICAL | |
---|---|
Size | |
(size excludes feet, knobs and terminals) | |
Single | 140 x 160 (1/3 rack, 4U) x 290mm |
Triple | 280 x 160 (2/3 rack, 4U) x 290mm |
Weight | |
Single | 5.5kg (12lb) |
Triple | 10.5kg (23lb) |
OPTIONS | |
---|---|
Rack Mount | RM410 19 inch 4U mount for up to three single output units or one triple plus one single. Blanking plates are supplied for unused sections. |
Accuracy specifications apply for the temperature range 18°C to 28°C after one hour warm-up.
Thurlby Thandar Instruments Ltd. operates a policy of co